LPV-18E

LPV-18E

Share:


LPV-18E



Features:
‧180-264VAC input only
‧Fully encapsulated with IP67 level (Note.5)
‧Protections: Short circuit / Overload / Over voltage / Over temperature
‧Cooling by free air convection
‧Class 2 unit ,no FG
‧Pass LPS
‧100% full load burn-in test
‧Suitable for LED lighting and moving sign applications
‧High reliability / Low cost
‧3 years warranty


Model LPV-18E-12 LPV-18E-24 LPV-18E-36
 
 
Output
DC voltage 12V 24V 36V
Rated current 1.5A 0.75A     0.5A
Current  range 0~1.5A 0~0.75A 0~0.5A
Rated  power 18W 18W 18W
Ripple&noise (max.) 120mVp-p 150mVp-p 200mVp-p
Voltage tolerance ±3.0%
Line regulation ±1.0%
Load regulation ±2.0%
Setup,rise time 1500ms,30ms / 230VAC
Hold up time 50ms/230VAC at full load
      Input Voltage range 180 ~ 264VAC , 254 ~ 370VDC
Frequency range 47 ~ 63Hz
Efficiency 77% 82% 83%
AC current 0.3A/230VAC
Inrush current Cold start 50A(twidth=155μs measured at 50% Ipeak) at 230VAC
Leakage current <0.25mA/240VAC
 
Protection
Overload Above 105% rated output power
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage 13.8~ 16.2V 27.6~ 32.4V 41.4~ 48.6V
Protection type : Shut off o/p voltage, clamping by zener diode
Over temperature Hiccup mode, recovers automatically after temperature goes down
 
Environment Working humidity 20%~90%RH  non-condensing
Storage temp,humidity -40℃~+80℃,10%~95%RH non-condensing
Temp. coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes
 
Safety&EMC
Safety standard         TUV EN60950-1, TUV EN61347-1,EN61347-2-13,IP67 approved; design refer to UL1310 Class 2,CAN/CSA No. 223-M91
Withstand voltage I/P-O/P:3KVAC
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to EN55022 Class B,EN61000-3-2 Class A, EN61000-3-3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Others MTBF 1100K hrs min. MIL-HDBK-217F (25℃)
Dimension 140*30*22(L*W*H)
Packing 0.175Kg; 70pcs/13.3Kgs/0.71CUFT
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.



 Inquiry - LPV-18E